Technical Review: ABB PSR9-600-70 Safety Relay - Selection Guide & Specs
Share
Overview
The ABB PSR9-600-70 safety relay addresses the critical industrial challenge of ensuring fail-safe emergency stop and safety circuit functionality in automated machinery and production lines. This compact safety module provides reliable monitoring of safety devices like emergency stop buttons, safety gates, light curtains, and two-hand controls, preventing hazardous machine operation when safety conditions are compromised.
Technical Analysis
The PSR9-600-70 represents ABB's advanced safety relay technology designed for Category 4/PL e applications according to EN ISO 13849-1. This unit features dual-channel monitoring with cross-circuit detection, ensuring maximum safety integrity for critical industrial applications. The relay is particularly valuable in applications involving Robotics, Packaging Machinery, and Material Handling systems where personnel protection is paramount.
| Specification | Value | Description |
|---|---|---|
| Product Code | PSR9-600-70 | ABB Safety Relay Module |
| Safety Category | Category 4 / PL e | Highest safety level per EN ISO 13849-1 |
| Supply Voltage | 24V DC | Standard industrial control voltage |
| Contact Configuration | 3 safety contacts (NO) | 2 normally open safety outputs, 1 auxiliary contact |
| Max Switching Current | 6A @ 24V DC | Sufficient for most safety circuit applications |
| Response Time | < 20ms | Fast reaction to safety input changes |
| Operating Temperature | -25°C to +55°C | Wide industrial temperature range |
| Dimensions | 22.5mm x 99mm x 114mm | Compact DIN rail mounting |
| Certifications | CE, UL, cULus | International safety standards compliance |
| MTTFd | > 100 years | Mean Time to Dangerous Failure |
The PSR9-600-70 features automatic start-up monitoring, short-circuit detection on outputs, and forced-guided contacts that prevent simultaneous closing of normally open and normally closed contacts. This design ensures that even in the event of contact welding, the safety function remains intact.
Buying Considerations
When selecting the ABB PSR9-600-70 safety relay for your application, consider these critical factors:
- Safety Category Requirements: Verify that your application requires Category 4/PL e protection. For lower-risk applications, consider Category 2 Safety Relays which may be more cost-effective.
- Input Device Compatibility: Ensure compatibility with your existing safety devices (emergency stops, safety switches, light curtains). The PSR9-600-70 supports dual-channel inputs with monitoring.
- Load Requirements: Calculate the total current draw of your safety-controlled devices. The 6A rating is sufficient for most applications, but verify against your specific load requirements.
- Environmental Conditions: Consider temperature, humidity, and vibration in your installation environment. The -25°C to +55°C operating range covers most industrial settings.
- System Integration: Plan for proper wiring and integration with your existing PLC Systems and control architecture.
- Certification Requirements: Confirm that the CE, UL, and cULus certifications meet your regional compliance needs.
For complex safety systems, consider consulting with a safety engineer to ensure proper risk assessment and system design.
Frequently Asked Questions
Q1: What is the main difference between the PSR9-600-70 and standard industrial relays?
The PSR9-600-70 is specifically designed for safety applications with forced-guided contacts, cross-circuit monitoring, and compliance with safety standards (Category 4/PL e). Standard relays lack these safety-critical features and cannot be used in personnel protection applications.
Q2: Can the PSR9-600-70 be used with single-channel safety devices?
While designed for dual-channel monitoring, the PSR9-600-70 can be configured for single-channel applications with appropriate external monitoring. However, this may reduce the safety category level, so consult the technical manual for proper configuration.
Q3: How do I properly test and maintain the PSR9-600-70 safety relay?
Regular functional testing is required per safety standards. Test the emergency stop circuit monthly by activating the safety input and verifying the safety outputs de-energize. Document all tests and inspections. For comprehensive maintenance guidance, refer to ABB's technical documentation available through Safety Relay Documentation resources.